Supplies - 243020-2016

15/07/2016    S135    - - Supplies - Additional information - Open procedure 

Romania-Timisoara: Rescue and emergency equipment

2016/S 135-243020

Inter Community Development Association for Emergency Situations Management — ADIVEST, Revolutiei str., no 17, Inter Community Development Association for Emergency Situations Management, Timisoara, Revolutiei str. no 17, postal code 300034, For the attention of: Mrs. Corina Grunfeld, Timisoara 300034, Romania. Telephone: +40 256494131. Fax: +40 256494596. E-mail: officeadivest@gmail.com

(Supplement to the Official Journal of the European Union, 16.6.2016, 2016/S 115-204802)

RE:
CPV:35112000

Rescue and emergency equipment

Instead of: 

Section II: Information about lots, Lot No: 1 Lot title: Inflatable dams 1) Short description

(...) In order to do this, all joints have fittings of 4” and 6” (Storz or equivalent).

(...)

(...)

Length of the tube (section): 6 sections of 50 meters each and 2 sections of 100 meters each.

(...)

(...)

— Weight: max. 40 kg.

(...)

(...)

Tests.

A 50 meter long section will be installed (during which the installing procedure will be checked, and the time required recorded).

(...)

Read: 

Section II: Information about lots, Lot No: 1 Lot title: Inflatable dams 1) Short description

(...) In order to do this, all joints have fittings of 4” and 6” (Storz or equivalent). Fittings of just 4" are acceptable, provided that a 6" adaptor is included.

(...)

(...)

Length of the tube (section): preferrable 6 sections of 50 meters each and 2 sections of 100 meters each. Sections of 200 meters and 100 meters length are acceptable.

(...)

(...)

- Weight: max. 40 kg. For water pumps (power pumps) bigger than 2”, a weight of 48-50 kg is acceptable.

(...)

(...)

Tests:

A 50 meter long section will be installed (during which the installing procedure will be checked, and the time required recorded

Tests:

If sections of 200 m/100 m are provided, the test will be performed on a 100 m long section: a 100 m long section will be installed (during which the installing procedure will be checked, and the time required recorded).

Other additional information

II.1.9. Information about variants:

According to point 1.4. in the „Instructions to tenderers” document, tenderers are not authorised to tender for a variant solution in addition to the present tender