See the notice on TED website
1. Beschaffer
1.1.
Beschaffer
Offizielle Bezeichnung: Danmarks Tekniske Universitet - DTU
Rechtsform des Erwerbers: Einrichtung des öffentlichen Rechts
Tätigkeit des öffentlichen Auftraggebers: Bildung
2. Verfahren
2.1.
Verfahren
Titel: Delivery of Gradient Coil for human magnetic resonance imaging
Beschreibung: DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.
Kennung des Verfahrens: 34152a87-f7a2-43e2-ae7d-172a1a32a57b
Interne Kennung: 10253
Verfahrensart: Verhandlungsverfahren ohne Aufruf zum Wettbewerb
2.1.1.
Zweck
Art des Auftrags: Lieferleistungen
Haupteinstufung (cpv): 38520000 Scanner
2.1.2.
Erfüllungsort
Beliebiger Ort
2.1.4.
Allgemeine Informationen
Rechtsgrundlage:
Richtlinie 2014/24/EU
5. Los
5.1.
Los: LOT-0000
Titel: Delivery of Ultrasonic Gradient Coil
Beschreibung: DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.
Interne Kennung: 10253
5.1.1.
Zweck
Art des Auftrags: Lieferleistungen
Haupteinstufung (cpv): 38520000 Scanner
5.1.2.
Erfüllungsort
Beliebiger Ort
5.1.6.
Allgemeine Informationen
Die Beschaffung fällt unter das Übereinkommen über das öffentliche Beschaffungswesen: ja
5.1.16.
Weitere Informationen, Schlichtung und Nachprüfung
Schlichtungsstelle: Konkurrence- og Forbrugerstyrelsen
Überprüfungsstelle: Klagenævnet for Udbud
Organisation, die zusätzliche Informationen über das Vergabeverfahren bereitstellt: Danmarks Tekniske Universitet - DTU
Organisation, die einen Offline-Zugang zu den Vergabeunterlagen bereitstellt: Danmarks Tekniske Universitet - DTU
6. Ergebnisse
Wert aller in dieser Bekanntmachung vergebenen Verträge: 129 966,94 EUR
Direktvergabe:
Begründung der Direktvergabe: Der Auftrag kann nur von einem bestimmten Wirtschaftsteilnehmer ausgeführt werden, da aus technischen Gründen kein Wettbewerb vorhanden ist
Sonstige Begründung: DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.
6.1.
Ergebnis, Los-– Kennung: LOT-0000
6.1.2.
Informationen über die Gewinner
Wettbewerbsgewinner:
Offizielle Bezeichnung: Futura Composites BV
Angebot:
Kennung des Angebots: 10253 Ultrasonic Gradient Coil
Kennung des Loses oder der Gruppe von Losen: LOT-0000
Informationen zum Auftrag:
Kennung des Auftrags: 10253 Ultrasonic Gradient Coil
Informationen zum Auftrag:
Kennung des Auftrags: 10253-Ultrasonic Gradient Coil
6.1.3.
Nicht erfolgreiche Bieter
Nicht erfolgreiche Bieter:
Offizielle Bezeichnung: Futura Composites BV
Angebot:
Kennung des Angebots: 10230092
Kennung des Loses oder der Gruppe von Losen: LOT-0000
8. Organisationen
8.1.
ORG-0001
Offizielle Bezeichnung: Danmarks Tekniske Universitet - DTU
Registrierungsnummer: 30060946
Postanschrift: Anker Engelunds Vej 1
Stadt: Kgs. Lyngby
Postleitzahl: 2800
Land, Gliederung (NUTS): Københavns omegn (DK012)
Land: Dänemark
Kontaktperson: Per Christiansen
Telefon: +45 45252525
Rollen dieser Organisation:
Beschaffer
Organisation, die zusätzliche Informationen über das Vergabeverfahren bereitstellt
Organisation, die einen Offline-Zugang zu den Vergabeunterlagen bereitstellt
8.1.
ORG-0002
Offizielle Bezeichnung: Klagenævnet for Udbud
Registrierungsnummer: 37795526
Postanschrift: Nævnenes hus, Toldboden 2
Stadt: Viborg
Postleitzahl: 8800
Land, Gliederung (NUTS): Østjylland (DK042)
Land: Dänemark
Telefon: +45 35291000
Rollen dieser Organisation:
Überprüfungsstelle
8.1.
ORG-0003
Offizielle Bezeichnung: Konkurrence- og Forbrugerstyrelsen
Registrierungsnummer: 10294819
Postanschrift: Carl Jacobsens Vej 35
Stadt: Valby
Postleitzahl: 2500
Land, Gliederung (NUTS): Byen København (DK011)
Land: Dänemark
Telefon: +45 41715000
Rollen dieser Organisation:
Schlichtungsstelle
8.1.
ORG-0004
Offizielle Bezeichnung: Futura Composites BV
Registrierungsnummer: NL809033628B01
Stadt: Heerhugowaard
Postleitzahl: 1704 RG
Land, Gliederung (NUTS): Noord-Friesland (NL127)
Land: Niederlande
Kontaktperson: M. Borgo
Telefon: +31 725715888
Rollen dieser Organisation:
Bieter
Gewinner dieser Lose: LOT-0000
8.1.
ORG-0005
Offizielle Bezeichnung: Mercell Holding ASA
Registrierungsnummer: 980921565
Postanschrift: Askekroken 11
Stadt: Oslo
Postleitzahl: 0277
Land, Gliederung (NUTS): Oslo (NO081)
Land: Norwegen
Kontaktperson: eSender
Telefon: +47 21018800
Fax: +47 21018801
Rollen dieser Organisation:
TED eSender
Informationen zur Bekanntmachung
Kennung/Fassung der Bekanntmachung: 8f04f827-6e32-4c21-ab26-797c84b88bcc - 01
Formulartyp: Vorankündigung – Direktvergabe
Art der Bekanntmachung: Freiwillige Ex-ante-Transparenzbekanntmachung
Unterart der Bekanntmachung: 25
Datum der Übermittlung der Bekanntmachung: 27/08/2025 07:20:17 (UTC+00:00) Westeuropäische Zeit, GMT
Bekanntmachung — eSender-Übermittlungsdatum: 27/08/2025 08:00:44 (UTC+00:00) Westeuropäische Zeit, GMT
Sprachen, in denen diese Bekanntmachung offiziell verfügbar ist: Englisch
Veröffentlichungsnummer der Bekanntmachung: 561640-2025
ABl. S – Nummer der Ausgabe: 164/2025
Datum der Veröffentlichung: 28/08/2025