<?xml version="1.0" encoding="UTF-8" standalone="no"?><ContractNotice xmlns="urn:oasis:names:specification:ubl:schema:xsd:ContractNotice-2" xmlns:cac="urn:oasis:names:specification:ubl:schema:xsd:CommonAggregateComponents-2" xmlns:cbc="urn:oasis:names:specification:ubl:schema:xsd:CommonBasicComponents-2" xmlns:efac="http://data.europa.eu/p27/eforms-ubl-extension-aggregate-components/1" xmlns:efbc="http://data.europa.eu/p27/eforms-ubl-extension-basic-components/1" xmlns:efext="http://data.europa.eu/p27/eforms-ubl-extensions/1" xmlns:ext="urn:oasis:names:specification:ubl:schema:xsd:CommonExtensionComponents-2">
   <ext:UBLExtensions>
      <ext:UBLExtension>
         <ext:ExtensionContent>
            <efext:EformsExtension>
               <efac:Changes>
                  <efbc:ChangedNoticeIdentifier>460656-2024</efbc:ChangedNoticeIdentifier>
                  <efac:Change>
                     <efbc:ChangeDescription languageID="POL">Zdolność techniczna lub zawodowej
Opis sposobu dokonywania oceny spełnienia tego warunku:
O zamówienie mogą ubiegać się Wykonawcy, którzy wykażą, że dysponują lub będą dysponować odpowiednim potencjałem osobowym zdolnym do wykonania zamówienia w tym:
a)osobami posiadającymi uprawnienia do projektowania wymagane przepisami ustawy Prawa Budowlanego, które to osoby w dniu podpisania umowy będą członkami właściwej izby samorządu zawodowego, zgodnie z ustawą Prawo budowlane oraz ustawą o samorządach zawodowych architektów, inżynierów budownictwa oraz urbanistów, posiadających co najmniej 5-letnie doświadczenie w projektowaniu liczone od momentu uzyskania uprawnień do pełnienia samodzielnych funkcji w budownictwie w specjalności, tj.:
•konstrukcyjno-budowlanej bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży konstrukcyjno-budowlanej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 40 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
oraz
- 1 projektu w branży konstrukcyjno-budowlanej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 3 000 m2.
•architektonicznej bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży architektonicznej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 40 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
oraz
- 1 projektu w branży architektonicznej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 3 000 m2.
•instalacyjnej bez ograniczeń w zakresie sieci, instalacji i urządzeń elektrycznych i elektroenergetycznych, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży elektrycznej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVAi posiadającym min.
40 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
•instalacyjnej bez ograniczeń w zakresie sieci, instalacji i urządzeń cieplnych, wentylacyjnych, gazowych, wodociągowych i kanalizacyjnych, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży instalacyjnej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 40 szaf rack, wykonywanej zgodnie z normą PN EN 50600 minimum w klasie 3 lub TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
oraz
- 1 projektu w branży instalacyjnej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 3 000 m2.
•systemu gaszenia posiadającego odpowiednie uprawnienia, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży ppoż. (gaszenie gazem obojętnym i wczesna detekcja) obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 40 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3lub TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
•drogowej bez ograniczeń lub inne równoważne zgodnie z przepisami ustawy z dnia 7 lipca 1994 r. Prawo budowlane i Rozporządzenia Ministra Transportu i Budownictwa z dnia 11 września 2014 r. w sprawie samodzielnych funkcji technicznych w budownictwie lub im odpowiadające ważne uprawnienia budowlane, które zostały wydane na podstawie wcześniej obowiązujących przepisów posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży drogowej obejmujący swoim zakresem zaprojektowanie parkingów, chodników, dróg dojazdowych, dróg wewnętrznych o powierzchni powyżej 5 000 m2;
•telekomunikacyjnej w zakresie sieci, instalacji i urządzeń teletechnicznych bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży telekomunikacyjnej obejmującym swoim zakresem obiekt serwerowni i posiadającym min. 40 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute;
ORAZ
•Konsultanta Data Center - minimum jedna osoba posiadająca udokumentowane doświadczenie jako konsultant przy doradztwie dla tworzonej wielobranżowej dokumentacji projektowej Data Center (obiekt serwerowni) o mocy min. 250 kVA i posiadającym min. 40 szaf rack, wykonywanej zgodnie z normą PN EN 50600 minimum w klasie 3.
b)O zamówienie mogą ubiegać się Wykonawcy, którzy wykażą, że w okresie ostatnich 5 lat przed upływem terminu składania ofert (a jeżeli okres działalności jest krótszy – w tym okresie):
zrealizowali co najmniej jedno zamówienie polegające na wykonaniu dokumentacji technicznej (projektowej) dla serwerowni (centrum przetwarzania danych) o wartości minimum 500 000,00 zł netto (za jedno zamówienie), zgodnie z normą PN-EN 50600 minimum w klasie 3 lub zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III dla Data Center wg. The Uptime Institute.</efbc:ChangeDescription>
                     <efbc:ProcurementDocumentsChangeDate>2024-08-30+02:00</efbc:ProcurementDocumentsChangeDate>
                     <efbc:ProcurementDocumentsChangeIndicator>true</efbc:ProcurementDocumentsChangeIndicator>
                     <efac:ChangedSection>
                        <efbc:ChangedSectionIdentifier>PROCEDURE</efbc:ChangedSectionIdentifier>
                     </efac:ChangedSection>
                  </efac:Change>
                  <efac:ChangeReason>
                     <cbc:ReasonCode listName="change-corrig-justification">update-add</cbc:ReasonCode>
                     <efbc:ReasonDescription languageID="POL">Zmiana treści SWZ oraz terminu składania ofert i terminu związania ofertą</efbc:ReasonDescription>
                  </efac:ChangeReason>
               </efac:Changes>
               <efac:NoticeSubType>
                  <cbc:SubTypeCode listName="notice-subtype">16</cbc:SubTypeCode>
               </efac:NoticeSubType>
               <efac:Organizations>
                  <efac:Organization>
                     <efac:Company>
                        <cbc:WebsiteURI>https://ssm.silesia.pl/</cbc:WebsiteURI>
                        <cbc:EndpointID>https://platformazakupowa.pl/transakcja/958033</cbc:EndpointID>
                        <cac:PartyIdentification>
                           <cbc:ID>ORG-0001</cbc:ID>
                        </cac:PartyIdentification>
                        <cac:PartyName>
                           <cbc:Name languageID="POL">Śląska Sieć Metropolitalna Sp. z o.o.</cbc:Name>
                        </cac:PartyName>
                        <cac:PostalAddress>
                           <cbc:StreetName>Bojkowska 37P</cbc:StreetName>
                           <cbc:CityName>Gliwice</cbc:CityName>
                           <cbc:PostalZone>44-100</cbc:PostalZone>
                           <cbc:CountrySubentityCode listName="nuts">PL229</cbc:CountrySubentityCode>
                           <cac:Country>
                              <cbc:IdentificationCode listName="country">POL</cbc:IdentificationCode>
                           </cac:Country>
                        </cac:PostalAddress>
                        <cac:PartyLegalEntity>
                           <cbc:CompanyID>6312578261</cbc:CompanyID>
                        </cac:PartyLegalEntity>
                        <cac:Contact>
                           <cbc:Name>https://platformazakupowa.pl/pn/ssm_silesia</cbc:Name>
                           <cbc:Telephone>+48 32 441 90 00</cbc:Telephone>
                           <cbc:ElectronicMail>biuro@ssm.silesia.pl</cbc:ElectronicMail>
                        </cac:Contact>
                     </efac:Company>
                  </efac:Organization>
                  <efac:Organization>
                     <efac:Company>
                        <cbc:WebsiteURI>https://https://www.uzp.gov.pl/kio</cbc:WebsiteURI>
                        <cbc:EndpointID>https://epuap.gov.pl/wps/portal/strefa-klienta/katalog-spraw/opis-uslugi/odwolanie-do-krajowej-izby-odwolawczej/UZP</cbc:EndpointID>
                        <cac:PartyIdentification>
                           <cbc:ID>ORG-0002</cbc:ID>
                        </cac:PartyIdentification>
                        <cac:PartyName>
                           <cbc:Name languageID="POL">Krajowa Izba Odwoławcza</cbc:Name>
                        </cac:PartyName>
                        <cac:PostalAddress>
                           <cbc:StreetName>Postępu 17A</cbc:StreetName>
                           <cbc:CityName>Warszawa</cbc:CityName>
                           <cbc:PostalZone>02-676</cbc:PostalZone>
                           <cbc:CountrySubentityCode listName="nuts">PL911</cbc:CountrySubentityCode>
                           <cac:Country>
                              <cbc:IdentificationCode listName="country">POL</cbc:IdentificationCode>
                           </cac:Country>
                        </cac:PostalAddress>
                        <cac:PartyLegalEntity>
                           <cbc:CompanyID>5262239325</cbc:CompanyID>
                        </cac:PartyLegalEntity>
                        <cac:Contact>
                           <cbc:Name>Sekretariat Biura Odwołań</cbc:Name>
                           <cbc:Telephone>+48 22 458 78 01</cbc:Telephone>
                           <cbc:Telefax>+48 22 458 78 00</cbc:Telefax>
                           <cbc:ElectronicMail>odwolania@uzp.gov.pl</cbc:ElectronicMail>
                        </cac:Contact>
                     </efac:Company>
                  </efac:Organization>
               </efac:Organizations>
            <efac:Publication><efbc:NoticePublicationID schemeName="ojs-notice-id">00524321-2024</efbc:NoticePublicationID><efbc:GazetteID schemeName="ojs-id">170/2024</efbc:GazetteID><efbc:PublicationDate>2024-09-02+02:00</efbc:PublicationDate></efac:Publication></efext:EformsExtension>
         </ext:ExtensionContent>
      </ext:UBLExtension>
   </ext:UBLExtensions>
   <cbc:UBLVersionID>2.3</cbc:UBLVersionID>
   <cbc:CustomizationID>eforms-sdk-1.11</cbc:CustomizationID>
   <cbc:ID schemeName="notice-id">9cce2adc-463a-4ee9-8c9c-157abda25a90</cbc:ID>
   <cbc:ContractFolderID>85b2ad96-3f05-45a3-81ae-a9f56eafb475</cbc:ContractFolderID>
   <cbc:IssueDate>2024-08-30Z</cbc:IssueDate>
   <cbc:IssueTime>11:10:01Z</cbc:IssueTime>
   <cbc:VersionID>01</cbc:VersionID>
   <cbc:RegulatoryDomain>32014L0024</cbc:RegulatoryDomain>
   <cbc:NoticeTypeCode listName="competition">cn-standard</cbc:NoticeTypeCode>
   <cbc:NoticeLanguageCode listName="language">POL</cbc:NoticeLanguageCode>
   <cac:ContractingParty>
      <cbc:BuyerProfileURI>https://platformazakupowa.pl/transakcja/958033</cbc:BuyerProfileURI>
      <cac:ContractingPartyType>
         <cbc:PartyTypeCode listName="buyer-legal-type">body-pl</cbc:PartyTypeCode>
      </cac:ContractingPartyType>
      <cac:ContractingActivity>
         <cbc:ActivityTypeCode listName="authority-activity">gen-pub</cbc:ActivityTypeCode>
      </cac:ContractingActivity>
      <cac:Party>
         <cac:PartyIdentification>
            <cbc:ID>ORG-0001</cbc:ID>
         </cac:PartyIdentification>
      </cac:Party>
   </cac:ContractingParty>
   <cac:TenderingTerms>
      <cac:TendererQualificationRequest>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">liq-admin</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 109 ust. 1 pkt 4 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">prep-confl</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 6 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">corruption</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">fraud</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">labour-law</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 lit. h i pkt 2
ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">socsec-pay</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 3 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">tax-pay</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 3 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">nati-ground</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Z postępowania o udzielenie zamówienia wyklucza się  Wykonawcę w przypadkach, o których mowa w art. 7 ust. 1 ustawy z dnia 13 kwietnia 2022 r. o szczególnych rozwiązaniach w zakresie przeciwdziałania wspieraniu agresji na Ukrainę oraz służących ochronie bezpieczeństwa narodowego (Dz.U. z 2023 r. poz. 1497 z późn. zm.). Do Wykonawcy podlegającego wykluczeniu w tym zakresie, stosuje się art. 7 ust. 3 wspomnianej ustawy. 
Wykluczeniu z postępowania podlegają Wykonawcy, zgodnie z art. 5k Rozporządzenia Rady (UE) nr 833/2014 z dnia 31 lipca 2014 r. dotyczącego środków ograniczających w związku z działaniami Rosji destabilizującymi sytuację na Ukrainie, dodanym Rozporządzeniem Rady (UE) 2022/576 z dnia 8 kwietnia 2022 r. w sprawie zmiany rozporządzenia (UE) nr 833/2014 dotyczącego środków  ograniczających w związku z działaniami Rosji destabilizującymi sytuację na Ukrainie (Dz.U.UE.L.2022.111.1 z dnia 2022.04.08).
</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">distorsion</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 5 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">human-traffic</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">finan-laund</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">terr-offence</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">crime-org</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 108 ust. 1 pkt 1 i 2 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">susp-act</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 109 ust. 1 pkt 4 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
         <cac:SpecificTendererRequirement>
            <cbc:TendererRequirementTypeCode listName="exclusion-ground">bankr-nat</cbc:TendererRequirementTypeCode>
            <cbc:Description languageID="POL">Dotyczy art. 109 ust. 1 pkt 4 ustawy Pzp</cbc:Description>
         </cac:SpecificTendererRequirement>
      </cac:TendererQualificationRequest>
   </cac:TenderingTerms>
   <cac:TenderingProcess>
      <ext:UBLExtensions>
         <ext:UBLExtension>
            <ext:ExtensionContent>
               <efext:EformsExtension>
                  <efbc:ProcedureRelaunchIndicator>false</efbc:ProcedureRelaunchIndicator>
               </efext:EformsExtension>
            </ext:ExtensionContent>
         </ext:UBLExtension>
      </ext:UBLExtensions>
      <cbc:ProcedureCode listName="procurement-procedure-type">open</cbc:ProcedureCode>
      <cac:ProcessJustification>
         <cbc:ProcessReasonCode listName="accelerated-procedure">false</cbc:ProcessReasonCode>
      </cac:ProcessJustification>
   </cac:TenderingProcess>
   <cac:ProcurementProject>
      <cbc:ID>SSM/9/PP/2024</cbc:ID>
      <cbc:Name languageID="POL">Wykonanie kompleksowej wielobranżowej dokumentacji projektowo-kosztorysowej dotyczącej budowy Miejskiego Data Center wraz z infrastrukturą towarzyszącą (przestrzeń administracyjno-biurowa, magazynowa oraz warsztatowa) w tym SOC i NOC wraz ze świadczeniem usług nadzoru autorskiego.</cbc:Name>
      <cbc:Description languageID="POL">Wykonanie kompleksowej wielobranżowej dokumentacji projektowo-kosztorysowej dotyczącej budowy Miejskiego Data Center wraz z infrastrukturą towarzyszącą (przestrzeń administracyjno-biurowa, magazynowa oraz warsztatowa) w tym SOC i NOC wraz ze świadczeniem usług nadzoru autorskiego. Szczegółowe informacje oraz kluczowe zapisy znajdują się
w SWZ i są udostępnione na stronie prowadzonego postępowania pod adresem platformy
zakupowej: https://platformazakupowa.pl/transakcja/958033
Informacje dodatkowe: 
1. Przez zastosowane pojęcie "ustawa Pzp" należy rozumieć ustawę z dnia 11 września 2019 r. Prawo Zamówień Publicznych (Dz. U. z 2023 r. poz. 1605 ze zm.). 
2.Opis sposobu przygotowania ofert zawarty został Specyfikacji Warunków Zamówienia (SWZ). 
3. Zamawiający przewiduje unieważnienie postępowania, jeśli środki publiczne, które zamierzał przeznaczyć na sfinansowanie całości lub części zamówienia nie zostały przyznane.
4. Zamawiający przeprowadził wstępne konsultacje rynkowe przed wszczęciem postępowania o udzielenie zamówienia. W związku z przeprowadzonymi konsultacjami rynkowymi protokół z przeprowadzenia Wstępnych Konsultacji Rynkowych stanowi załącznik do SWZ.
5. Termin zakończenia realizacji zamówienia: zgodnie z zapisami projektowanych postanowień umowy.</cbc:Description>
      <cbc:ProcurementTypeCode listName="contract-nature">services</cbc:ProcurementTypeCode>
      <cac:MainCommodityClassification>
         <cbc:ItemClassificationCode listName="cpv">71000000</cbc:ItemClassificationCode>
      </cac:MainCommodityClassification>
      <cac:AdditionalCommodityClassification>
         <cbc:ItemClassificationCode listName="cpv">71220000</cbc:ItemClassificationCode>
      </cac:AdditionalCommodityClassification>
      <cac:AdditionalCommodityClassification>
         <cbc:ItemClassificationCode listName="cpv">71242000</cbc:ItemClassificationCode>
      </cac:AdditionalCommodityClassification>
      <cac:AdditionalCommodityClassification>
         <cbc:ItemClassificationCode listName="cpv">71248000</cbc:ItemClassificationCode>
      </cac:AdditionalCommodityClassification>
      <cac:AdditionalCommodityClassification>
         <cbc:ItemClassificationCode listName="cpv">71320000</cbc:ItemClassificationCode>
      </cac:AdditionalCommodityClassification>
      <cac:RealizedLocation>
         <cac:Address>
            <cbc:CityName>Gliwice</cbc:CityName>
            <cbc:PostalZone>44-100</cbc:PostalZone>
            <cbc:CountrySubentityCode listName="nuts">PL229</cbc:CountrySubentityCode>
            <cac:Country>
               <cbc:IdentificationCode listName="country">POL</cbc:IdentificationCode>
            </cac:Country>
         </cac:Address>
      </cac:RealizedLocation>
   </cac:ProcurementProject>
   <cac:ProcurementProjectLot>
      <cbc:ID schemeName="Lot">LOT-0001</cbc:ID>
      <cac:TenderingTerms>
         <ext:UBLExtensions>
            <ext:UBLExtension>
               <ext:ExtensionContent>
                  <efext:EformsExtension>
                     <efac:SelectionCriteria>
                        <cbc:CriterionTypeCode listName="selection-criterion">tp-abil</cbc:CriterionTypeCode>
                        <cbc:Name languageID="POL">Zdolność techniczna i zawodowa - zgodnie z rozdziałem XII SWZ</cbc:Name>
                        <cbc:Description languageID="POL">1.	O zamówienie mogą ubiegać się Wykonawcy, którzy wykażą, że dysponują lub będą dysponować odpowiednim potencjałem osobowym zdolnym do wykonania zamówienia w tym:
a)	osobami posiadającymi uprawnienia do projektowania wymagane przepisami ustawy Prawa Budowlanego, które to osoby w dniu podpisania umowy będą członkami właściwej izby samorządu zawodowego, zgodnie z ustawą Prawo budowlane oraz ustawą o samorządach zawodowych architektów, inżynierów budownictwa oraz urbanistów, posiadających co najmniej 5-letnie doświadczenie w projektowaniu liczone od momentu uzyskania uprawnień do pełnienia samodzielnych funkcji w budownictwie w specjalności, tj.:
•	konstrukcyjno-budowlanej bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży konstrukcyjno-budowlanej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA  i posiadającym min. 48 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub  zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
oraz
- 1 projektu w branży konstrukcyjno-budowlanej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 4 000 m2.
•	architektonicznej bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży architektonicznej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 48 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub  zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
oraz
- 1 projektu w branży architektonicznej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 4 000 m2.
•	instalacyjnej bez ograniczeń w zakresie sieci, instalacji i urządzeń elektrycznych i elektroenergetycznych, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży elektrycznej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 48 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub  zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
•	instalacyjnej bez ograniczeń w zakresie sieci, instalacji i urządzeń cieplnych, wentylacyjnych, gazowych, wodociągowych i kanalizacyjnych, posiadającą udokumentowane doświadczenie w opracowaniu minimum:
- 1 projektu w branży instalacyjnej obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 48 szaf rack, wykonywanej zgodnie z normą PN EN 50600 minimum w klasie 3 lub TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
oraz
- 1 projektu w branży instalacyjnej obejmującym swym zakresem obiekt administracyjno-biurowy o powierzchni użytkowej powyżej 4 000 m2.
•	systemu gaszenia posiadającego odpowiednie uprawnienia, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży ppoż. (gaszenie gazem obojętnym i wczesna detekcja) obejmującym swoim zakresem obiekt serwerowni o mocy min. 250 kVA i posiadającym min. 48 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3lub TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
•	drogowej bez ograniczeń lub inne równoważne zgodnie z przepisami ustawy z dnia 7 lipca 1994 r. Prawo budowlane i Rozporządzenia Ministra Transportu i Budownictwa z dnia 11 września 2014 r. w sprawie samodzielnych funkcji technicznych w budownictwie lub im odpowiadające ważne uprawnienia budowlane, które zostały wydane na podstawie wcześniej obowiązujących przepisów posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży drogowej obejmujący swoim zakresem zaprojektowanie parkingów, chodników, dróg dojazdowych, dróg wewnętrznych 
o powierzchni powyżej 5 000 m2;
•	telekomunikacyjnej w zakresie sieci, instalacji i urządzeń teletechnicznych bez ograniczeń, posiadającą udokumentowane doświadczenie w opracowaniu minimum 1 projektu w branży telekomunikacyjnej obejmującym swoim zakresem obiekt serwerowni 
i posiadającym min. 48 szaf rack, wykonywanym zgodnie z normą PN EN 50600 minimum w klasie 3 lub  zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...);
ORAZ
•	Konsultanta Data Center - minimum jedna osoba posiadająca udokumentowane doświadczenie jako konsultant przy doradztwie dla tworzonej wielobranżowej dokumentacji projektowej Data Center (obiekt serwerowni) o mocy min. 250 kVA i posiadającym min. 48 szaf rack, wykonywanej zgodnie z normą PN EN 50600 minimum w klasie 3.
b)	O zamówienie mogą ubiegać się Wykonawcy, którzy wykażą, że w okresie ostatnich 5 lat przed upływem terminu składania ofert (a jeżeli okres działalności jest krótszy – w tym okresie):
•	zrealizowali co najmniej jedno zamówienie polegające na wykonaniu dokumentacji projektowej dla budynku administracyjno-biurowego w której zakres wchodziły: projekt budowlany, projekty wykonawcze, przedmiary robót, kosztorysy inwestorskie, informacja BIOZ obejmującą co najmniej branżę: architektoniczną, konstrukcyjno-budowlaną, instalacji sanitarnych, elektryczną, drogową wraz z projektem zagospodarowania terenu.
oraz
•	•	zrealizowali co najmniej jedno zamówienie polegające na wykonaniu dokumentacji technicznej (projektowej) dla serwerowni (centrum przetwarzania danych) o wartości minimum 500 000,00 zł netto zgodnie z normą PN-EN 50600 w klasie 3 lub  zgodnie z normą TIA-942 (ANSI/TIA-942, 942-2, 942A- Telecommunications Infrastructure Standard for Data Center) Rating 3 lub zgodnie z TIER III (...)</cbc:Description>
                        <cbc:CalculationExpressionCode listName="usage">used</cbc:CalculationExpressionCode>
                     </efac:SelectionCriteria>
                     <efac:StrategicProcurement>
                        <efbc:ApplicableLegalBasis listName="cvd-scope">false</efbc:ApplicableLegalBasis>
                     </efac:StrategicProcurement>
                  </efext:EformsExtension>
               </ext:ExtensionContent>
            </ext:UBLExtension>
         </ext:UBLExtensions>
         <cbc:VariantConstraintCode listName="permission">not-allowed</cbc:VariantConstraintCode>
         <cbc:FundingProgramCode listName="eu-funded">no-eu-funds</cbc:FundingProgramCode>
         <cbc:RecurringProcurementIndicator>false</cbc:RecurringProcurementIndicator>
         <cac:RequiredFinancialGuarantee>
            <cbc:GuaranteeTypeCode listName="tender-guarantee-required">false</cbc:GuaranteeTypeCode>
         </cac:RequiredFinancialGuarantee>
         <cac:CallForTendersDocumentReference>
            <ext:UBLExtensions>
               <ext:UBLExtension>
                  <ext:ExtensionContent>
                     <efext:EformsExtension>
                        <efac:OfficialLanguages>
                           <cac:Language>
                              <cbc:ID>POL</cbc:ID>
                           </cac:Language>
                        </efac:OfficialLanguages>
                     </efext:EformsExtension>
                  </ext:ExtensionContent>
               </ext:UBLExtension>
            </ext:UBLExtensions>
            <cbc:ID>_DEFAULT_VALUE_CHANGE_ME_</cbc:ID>
            <cbc:DocumentType>non-restricted-document</cbc:DocumentType>
            <cac:Attachment>
               <cac:ExternalReference>
                  <cbc:URI>https://platformazakupowa.pl/transakcja/958033</cbc:URI>
               </cac:ExternalReference>
            </cac:Attachment>
         </cac:CallForTendersDocumentReference>
         <cac:TendererQualificationRequest>
            <cac:SpecificTendererRequirement>
               <cbc:TendererRequirementTypeCode listName="reserved-procurement">none</cbc:TendererRequirementTypeCode>
            </cac:SpecificTendererRequirement>
         </cac:TendererQualificationRequest>
         <cac:ContractExecutionRequirement>
            <cbc:ExecutionRequirementCode listName="reserved-execution">no</cbc:ExecutionRequirementCode>
         </cac:ContractExecutionRequirement>
         <cac:ContractExecutionRequirement>
            <cbc:ExecutionRequirementCode listName="einvoicing">allowed</cbc:ExecutionRequirementCode>
         </cac:ContractExecutionRequirement>
         <cac:ContractExecutionRequirement>
            <cbc:ExecutionRequirementCode listName="nda">false</cbc:ExecutionRequirementCode>
         </cac:ContractExecutionRequirement>
         <cac:ContractExecutionRequirement>
            <cbc:ExecutionRequirementCode listName="ecatalog-submission">not-allowed</cbc:ExecutionRequirementCode>
         </cac:ContractExecutionRequirement>
         <cac:ContractExecutionRequirement>
            <cbc:ExecutionRequirementCode listName="esignature-submission">true</cbc:ExecutionRequirementCode>
         </cac:ContractExecutionRequirement>
         <cac:AwardingTerms>
            <cac:AwardingCriterion>
               <cac:SubordinateAwardingCriterion>
                  <ext:UBLExtensions>
                     <ext:UBLExtension>
                        <ext:ExtensionContent>
                           <efext:EformsExtension>
                              <efac:AwardCriterionParameter>
                                 <efbc:ParameterCode listName="number-weight">poi-exa</efbc:ParameterCode>
                                 <efbc:ParameterNumeric>60</efbc:ParameterNumeric>
                              </efac:AwardCriterionParameter>
                           </efext:EformsExtension>
                        </ext:ExtensionContent>
                     </ext:UBLExtension>
                  </ext:UBLExtensions>
                  <cbc:AwardingCriterionTypeCode listName="award-criterion-type">price</cbc:AwardingCriterionTypeCode>
                  <cbc:Description languageID="POL">Cena ofertowa brutto całego zamówienia (C)
</cbc:Description>
               </cac:SubordinateAwardingCriterion>
               <cac:SubordinateAwardingCriterion>
                  <ext:UBLExtensions>
                     <ext:UBLExtension>
                        <ext:ExtensionContent>
                           <efext:EformsExtension>
                              <efac:AwardCriterionParameter>
                                 <efbc:ParameterCode listName="number-weight">poi-exa</efbc:ParameterCode>
                                 <efbc:ParameterNumeric>40</efbc:ParameterNumeric>
                              </efac:AwardCriterionParameter>
                           </efext:EformsExtension>
                        </ext:ExtensionContent>
                     </ext:UBLExtension>
                  </ext:UBLExtensions>
                  <cbc:AwardingCriterionTypeCode listName="award-criterion-type">quality</cbc:AwardingCriterionTypeCode>
                  <cbc:Description languageID="POL">Doświadczenie zawodowe projektantów realizujących prace projektowe (D)
Doświadczeni projektanci posiadający uprawnienia budowlane do projektowania w specjalności: 
A.	Branży architektonicznej – bez ograniczeń (max 10 pkt)
Wykonawca otrzyma punkty w następujący sposób:
Jeżeli projektant był autorem dokumentacji projektowej
- za 2 wykonane projekty serwerowni, otrzyma – 5 pkt
- za 3 wykonane projekty serwerowni, otrzyma – 7 pkt
- za 5 wykonanych projektów serwerowni, otrzyma – 10 pkt
B.	Branży konstrukcyjno-budowlanej – bez ograniczeń (max 10 pkt)
Wykonawca otrzyma punkty w następujący sposób:
Jeżeli projektant był autorem dokumentacji projektowej
- za 2 wykonane projekty serwerowni, otrzyma – 5 pkt
- za 3 wykonane projekty serwerowni, otrzyma – 7 pkt
- za 5 wykonanych projektów serwerowni, otrzyma – 10 pkt
C.	Konsultant DC (max 20 pkt)
Wykonawca otrzyma punkty w następujący sposób:
Jeżeli konsultant brał udział projektowaniu 
- 2 serwerowni, otrzyma –  5 pkt
- 3 serwerowni, otrzyma – 10 pkt
- 5 serwerowni, otrzyma – 20 pkt
</cbc:Description>
               </cac:SubordinateAwardingCriterion>
            </cac:AwardingCriterion>
         </cac:AwardingTerms>
         <cac:AdditionalInformationParty>
            <cac:PartyIdentification>
               <cbc:ID>ORG-0001</cbc:ID>
            </cac:PartyIdentification>
         </cac:AdditionalInformationParty>
         <cac:DocumentProviderParty>
            <cac:PartyIdentification>
               <cbc:ID>ORG-0001</cbc:ID>
            </cac:PartyIdentification>
         </cac:DocumentProviderParty>
         <cac:TenderRecipientParty>
            <cbc:EndpointID>https://platformazakupowa.pl/transakcja/958033</cbc:EndpointID>
            <cac:PartyIdentification>
               <cbc:ID>ORG-0001</cbc:ID>
            </cac:PartyIdentification>
         </cac:TenderRecipientParty>
         <cac:TenderEvaluationParty>
            <cac:PartyIdentification>
               <cbc:ID>ORG-0001</cbc:ID>
            </cac:PartyIdentification>
         </cac:TenderEvaluationParty>
         <cac:TenderValidityPeriod>
            <cbc:DurationMeasure unitCode="DAY">90</cbc:DurationMeasure>
         </cac:TenderValidityPeriod>
         <cac:AppealTerms>
            <cac:AppealInformationParty>
               <cac:PartyIdentification>
                  <cbc:ID>ORG-0002</cbc:ID>
               </cac:PartyIdentification>
            </cac:AppealInformationParty>
            <cac:AppealReceiverParty>
               <cac:PartyIdentification>
                  <cbc:ID>ORG-0002</cbc:ID>
               </cac:PartyIdentification>
            </cac:AppealReceiverParty>
         </cac:AppealTerms>
         <cac:Language>
            <cbc:ID>POL</cbc:ID>
         </cac:Language>
         <cac:PostAwardProcess>
            <cbc:ElectronicOrderUsageIndicator>true</cbc:ElectronicOrderUsageIndicator>
            <cbc:ElectronicPaymentUsageIndicator>true</cbc:ElectronicPaymentUsageIndicator>
         </cac:PostAwardProcess>
      </cac:TenderingTerms>
      <cac:TenderingProcess>
         <ext:UBLExtensions>
            <ext:UBLExtension>
               <ext:ExtensionContent>
                  <efext:EformsExtension>
                     <efbc:ProcedureRelaunchIndicator>false</efbc:ProcedureRelaunchIndicator>
                  </efext:EformsExtension>
               </ext:ExtensionContent>
            </ext:UBLExtension>
         </ext:UBLExtensions>
         <cbc:SubmissionMethodCode listName="esubmission">required</cbc:SubmissionMethodCode>
         <cbc:GovernmentAgreementConstraintIndicator>false</cbc:GovernmentAgreementConstraintIndicator>
         <cac:TenderSubmissionDeadlinePeriod>
            <cbc:EndDate>2024-09-09+02:00</cbc:EndDate>
            <cbc:EndTime>11:00:00+02:00</cbc:EndTime>
         </cac:TenderSubmissionDeadlinePeriod>
         <cac:OpenTenderEvent>
            <cbc:OccurrenceDate>2024-09-09+02:00</cbc:OccurrenceDate>
            <cbc:OccurrenceTime>11:05:00+02:00</cbc:OccurrenceTime>
         </cac:OpenTenderEvent>
         <cac:AuctionTerms>
            <cbc:AuctionConstraintIndicator>false</cbc:AuctionConstraintIndicator>
         </cac:AuctionTerms>
         <cac:ContractingSystem>
            <cbc:ContractingSystemTypeCode listName="framework-agreement">none</cbc:ContractingSystemTypeCode>
         </cac:ContractingSystem>
         <cac:ContractingSystem>
            <cbc:ContractingSystemTypeCode listName="dps-usage">none</cbc:ContractingSystemTypeCode>
         </cac:ContractingSystem>
      </cac:TenderingProcess>
      <cac:ProcurementProject>
         <cbc:ID>SSM/9/PP/2024</cbc:ID>
         <cbc:Name languageID="POL">Wykonanie kompleksowej wielobranżowej dokumentacji projektowo-kosztorysowej dotyczącej budowy Miejskiego Data Center wraz z infrastrukturą towarzyszącą (przestrzeń administracyjno-biurowa, magazynowa oraz warsztatowa) w tym SOC i NOC wraz ze świadczeniem usług nadzoru autorskiego</cbc:Name>
         <cbc:Description languageID="POL">Wykonanie kompleksowej wielobranżowej dokumentacji projektowo-kosztorysowej dotyczącej budowy Miejskiego Data Center wraz z infrastrukturą towarzyszącą (przestrzeń administracyjno-biurowa, magazynowa oraz warsztatowa) w tym SOC i NOC wraz ze świadczeniem usług nadzoru autorskiego. Szczegółowe informacje oraz kluczowe zapisy znajdują się
w SWZ i są udostępnione na stronie prowadzonego postępowania pod adresem platformy
zakupowej: https://platformazakupowa.pl/transakcja/958033</cbc:Description>
         <cbc:ProcurementTypeCode listName="contract-nature">services</cbc:ProcurementTypeCode>
         <cbc:SMESuitableIndicator>true</cbc:SMESuitableIndicator>
         <cac:MainCommodityClassification>
            <cbc:ItemClassificationCode listName="cpv">71000000</cbc:ItemClassificationCode>
         </cac:MainCommodityClassification>
         <cac:AdditionalCommodityClassification>
            <cbc:ItemClassificationCode listName="cpv">71220000</cbc:ItemClassificationCode>
         </cac:AdditionalCommodityClassification>
         <cac:AdditionalCommodityClassification>
            <cbc:ItemClassificationCode listName="cpv">71242000</cbc:ItemClassificationCode>
         </cac:AdditionalCommodityClassification>
         <cac:AdditionalCommodityClassification>
            <cbc:ItemClassificationCode listName="cpv">71248000</cbc:ItemClassificationCode>
         </cac:AdditionalCommodityClassification>
         <cac:AdditionalCommodityClassification>
            <cbc:ItemClassificationCode listName="cpv">71320000</cbc:ItemClassificationCode>
         </cac:AdditionalCommodityClassification>
         <cac:RealizedLocation>
            <cac:Address>
               <cbc:CityName>Gliwice</cbc:CityName>
               <cbc:PostalZone>44-100</cbc:PostalZone>
               <cbc:CountrySubentityCode listName="nuts">PL229</cbc:CountrySubentityCode>
               <cac:Country>
                  <cbc:IdentificationCode listName="country">POL</cbc:IdentificationCode>
               </cac:Country>
            </cac:Address>
         </cac:RealizedLocation>
         <cac:PlannedPeriod>
            <cbc:DescriptionCode listName="timeperiod">UNKNOWN</cbc:DescriptionCode>
         </cac:PlannedPeriod>
         <cac:ContractExtension>
            <cbc:OptionsDescription languageID="POL">Zamawiający przewiduje możliwość skorzystania z prawa opcji o którym mowa w art. 441 ustawy Pzp, w zakresie sprawowania nadzoru autorskiego nad opracowaną dokumentacją – od momentu wprowadzenia przyszłego Wykonawcy robót budowlanych na teren budowy do dnia uzyskania decyzji o pozwoleniu na użytkowanie dla każdego etapu budowy odrębnie.
Zamawiający zastrzega, że część zamówienia określona jako prawo opcji jest uprawnieniem, a nie zobowiązaniem Zamawiającego, z którego może nie skorzystać, skorzystać z niego w mniejszym zakresie aniżeli określony powyżej, w szczególności w przypadku nieuzyskania środków finansowych na ten cel lub innych decyzji uniemożliwiających rozpoczęcie prac budowlanych (czy faktycznie na podstawie projektu dojdzie do realizacji obiektu).
Warunki oraz zasady korzystania z prawa opcji szerzej zostały opisane w §3 Projektowanych postanowieniach umowy – załącznik nr 4 do SWZ.</cbc:OptionsDescription>